Command Groups
Table 2-5: Status commands (cont.)
Command
Description
STATus:QUEStionable:INSTrument:ISUMmary<x>:CONDition?
Return questionable condition register summary for channel
x, where <x> is 1, 2, or 3. When a bit of the quest condition
changes, the corresponding bit value in the quest event register
will be set to x.
Set/query questionable enable register. This parameter
determines which bit of the quest event register is set to 1. If a
QUES condition changes, the QUES bit of status byte register
will be set to 1.
Return questionable event register.
STATus:OPERation:INSTrument[:ENABle]?
Set/query operation enable register. The parameter determines
which bit value of quest event register is set to 1. If a OPER
condition changes, the OPER bit of the status byte register will
be set to 1.
STATus:OPERation:INSTrument[:EVENt]?
Return operation event register.
STATus:OPERation:INSTrument[:EVENt]?
Queries the contents of the operation instrument event register
(OIEVR).
STATus:OPERation:INSTrument[:ENABle]?
Queries the contents of the operation instrument enable register
(OIENR).
STATus:OPERation:INSTrument:ISUmmary<x>[:EVENt]?
Return operation event register for channel x, where <x> is 1,
2, or 3.
STATus:OPERation:INSTrument:ISUmmary<x>:ENABle
Set/query operation enable register for channel x, where <x> is
1, 2, or 3. The parameter determines which bit value of quest
event register is set to 1. If a OPER condition changes, the
OPER bit of the status byte register will be set to 1.
STATus:OPERation:INSTrument:ISUMmary<x>:CONDition?
Return operation condition register for channel x, where <x> is
1, 2, or 3. When a parameter of the operation condition register
changes, the corresponding bit in the operation event register
will be set to 1.
Save and Recall Commands
Save and recall commands allow you to save the active settings to one of the
settings memories within the power supply, and recall those settings at a later time.
Table 2-6: Save and recall commands
Header
Description
Save instrument setting to setup memory
Recall instrument setting from setup memory
2-8
Series 2200 Programmable Multichannel DC Power Supplies Programmer Manual
Summary of Contents for KEITHLEY 2200 Series
Page 2: ......
Page 6: ......
Page 11: ...Getting Started...
Page 12: ......
Page 65: ...Status and Events...
Page 66: ......
Page 81: ...Appendices...
Page 82: ......
Page 103: ......