The Graphical Waveform Editor
AWG610 Arbitrary Waveform Generator User Manual
3-51
Table 3-10: Standard Function Waveform dialog box parameters
Parameter
Description
Type
Specifies the type of standard function waveform to create. You can select
Sine, Triangle, Square, Ramp, DC, Gaussian Noise, or Random Noise.
Operation
Selects how the standard function waveform is added to the edit area.
Replace replaces the edit area data with the specified standard function
waveform. This operation does not change the waveform data record length.
Insert interpolates the standard function waveform starting at the active cursor
position. This operation increases the waveform data record length by the
amount of the inserted waveform.
Add replaces the edit area data with the sum of the current edit area data and
the specified standard function waveform. This operation does not change the
waveform data record length.
Mul replaces the edit area data with the product of the current edit area data
and the standard function waveform. This operation does not change the
waveform data record length.
Cycle
Specifies the number of function waveform cycles to insert in the specified
cursor area. The range of values is from 0.1 to 100,000 in 0.1 increments. The
default value is 1 cycle.
If the Operation field is set to Replace, Add, or Mul, the Cycle field value
determines the Frequency field value according to the equation
Frequency = Cycle x clock frequency / data length.
Frequency
Specifies the frequency of the function waveform to insert in the specified
cursor area. The range of values is from 0.1 to 500 MHz, with 9Ćdigit accuracy.
If the Operation field is set to Replace, Add, or Mul, the Frequency field
determines the Cycle field value according to the equation
Cycle = Frequency x data length / clock frequency.
Amplitude, or
RMS
Specifies the standard function waveform's DAC range. The range of values is
from -1.0 to 1.0 in
0.0001 increments. Specifying a negative value creates a
waveform whose first cycle starts with a negative transition (in other words, a
180
°
phase shift). Refer to the note on page 2-58 for more information on
DAC values.
If
you selected Gaussian Noise, this parameter turns to RMS. You can use
Root Mean Square to specify the signal amplitude.
Offset
Specifies the function waveform offset value. The range of values is from -1.0
to 1.0 in 0.0001 increments. The default offset is 0.
The Cut command deletes the edit area waveform and marker data and places the
deleted data in the paste buffer. The waveform data length decreases by the
amount of data deleted. If you unintentionally delete data, you can use the Undo!
bottom button to undo the cut operation.
Cut
Summary of Contents for AWG610
Page 4: ......
Page 24: ...Preface AWG610 Arbitrary Waveform Generator User Manual...
Page 216: ...Quick Editing AWG610 Arbitrary Waveform Generator User Manual...
Page 220: ...The Table Editor AWG610 Arbitrary Waveform Generator User Manual...
Page 242: ...The Sequence Editor AWG610 Arbitrary Waveform Generator User Manual...
Page 288: ...The UTILITY Window AWG610 Arbitrary Waveform Generator User Manual...
Page 292: ...Capturing Waveforms AWG610 Arbitrary Waveform Generator User Manual...
Page 326: ...Programming Examples AWG610 Arbitrary Waveform Generator User Manual...
Page 338: ...File Management AWG610 Arbitrary Waveform Generator User Manual...
Page 424: ...Appendix B Performance Verification AWG610 Arbitrary Waveform Generator User Manual...
Page 440: ...Appendix E File Transfer Interface Outline AWG610 Arbitrary Waveform Generator User Manual...