1710J-Series Waveform Monitors
1–1
Getting Started
This section of the manual has the product description, list of accessories,
installation instructions, and a functional check of operation.
Product Description
The Tektronix 1710J-Series is a specialized oscilloscope. It is designed to
monitor and measure baseband video signals. It offers a choice of three basic
sweep rates: two field, two line, and 1 line, each of which can be magnified to
provide three additional sweep rates, 1
m
s (two line), 0.2
m
s (1one line), and X25
(two field). The two-field sweep rate, both magnified and unmagnified displays
the complete vertical interval.
The Channel A and B Composite Video Inputs and the External Reference
Signal Input are high impedance bridging loop-throughs to protect the integrity
of the signal paths. The input switching allows for the display of either Chan-
nel A or Channel B Input or both inputs. Synchronization can be either internal
or external.
The vertical signal processing provides slow DC restoration that clamps the
display while still showing any 50 or 60 Hz hum components. The input signal
can be unfiltered (Flat) or either Low Pass or Chrominance filtered. There is also
a combination of Flat and Low Pass filtering available when a 2 Line or 2 Field
sweep rate is employed; the display consists of one line or field low pass filtered
while the second is unfiltered. Vertical amplitudes can be displayed in a
calibrated gain mode, which corresponds directly with the graticule vertical
scales, magnified five times.
An RGB or YRGB Parade display, for camera setup, is accommodated with a
shortened sweep. The input of the camera signal and an enable are through the
rear-panel REMOTE connector. The choice of three-step (RGB) or four-step
(YRGB) is made by changing the status of a control line through the REMOTE
connector.
The CRT is a mesh type, which has better geometry. In addition, it uses an
internal graticule to reduce parallax. Variable graticule scale illumination
provides even lighting to improve measurement accuracy and the quality of
waveform pictures. Option 74 provides a P4 (white) phosphor tube.
Summary of Contents for 1710J Series
Page 4: ......
Page 14: ...Table of Contents x 1710J Series Waveform Monitors ...
Page 18: ...Service Safety Summary xiv 1710J Series Waveform Monitors ...
Page 22: ...Preface xviii 1710J Series Waveform Monitors ...
Page 23: ...Getting Started ...
Page 24: ......
Page 45: ...Operating Basics ...
Page 46: ......
Page 55: ...Reference ...
Page 56: ......
Page 64: ...Reference 3 8 1710J Series Waveform Monitors ...
Page 65: ...Specifications ...
Page 66: ......
Page 74: ...Specifications 4 8 1710J Series Waveform Monitors ...
Page 76: ......
Page 77: ...Theory of Operation ...
Page 78: ......
Page 100: ...Theory of Operation 5 22 1710J Series Waveform Monitors ...
Page 101: ...Performance Verification ...
Page 102: ......
Page 120: ...Performance Verification 6 18 1710J Series Waveform Monitors ...
Page 121: ...Adjustment Procedure ...
Page 122: ......
Page 138: ...Adjustment Procedure 7 16 1710J Series Waveform Monitors ...
Page 139: ...Maintenance ...
Page 140: ......
Page 169: ...Replaceable Electrical Parts ...
Page 170: ......
Page 204: ...Replaceable Electrical Parts 9 34 1710J Series Waveform Monitors ...
Page 205: ...Diagrams ...
Page 206: ......
Page 226: ......
Page 227: ...Replaceable Mechanical Parts ...
Page 228: ......
Page 240: ...Replaceable Mechanical Parts 11 12 1710J Series Waveform Monitors ...
Page 244: ...Glossary Glossary 4 1710J Series Waveform Monitors ...
Page 251: ......
Page 252: ......