Assembly instructions for sliding doors with CarTeck 252 electric drive
Important:
The electric drive stated below (Marantec, type 252) should only be used for doors with a leaf area of
≤
25m
2
. This drive is not permitted for larger leaf areas.
-
Open the door in order to install the guide rail.
-
Use the fixing brackets to install the guide rail in front of the runner rail (see diagram)
-
Lengthwise, the guide rail should be set so that the end position of the door link bracket in the guide rail is at
least 100mm behind the fully open door, i.e. that the door link bracket can never move to the end of the rail.
The same applies for the closed position.
door end position OPEN
runner rail
door link bracket
A warning sign should be
placed in the area of the
wall soffit for doors with
Marantec automatic operation.
This sign has to warn of the
potential dangers resulting
from automatic door closing
ab
do
solute end position
or link bracket
drive rail
drive head
opening direction
~100
W arning!
Never place hands or other objects
between the wall and door
Programming the electric drive in accordance with the CarTeck Installation and Operating Instructions Parts 1+ 2.
Before programming the electric drive it is important to check whether the door runs freely in the parallel running
guide rail. The door link bracket of the guide rail has to be unlocked for this task (see Fig. D10 - D12, Installation
Instructions Part 2). Subsequently check whether the door and guide rail run smoothly without jamming along the
entire travel of the door (end position open and closed).
Ensure that the door link bracket has locked into place in the guide rail prior to programming! (see D23,
Installation Instructions Part 2)
-
Programming procedure for basic drive functions page 26 of the Installation and Operating Instructions Part 1
-
Programming end position OPEN and CLOSED page 28 – 29. Caution: When programming the end position
CLOSED, ensure that the rubber trims of the main contact leaf edges are not resting on each other! The
distance between the rubber trims has to be approx. 2 – 5mm (see diagram)
-
Programming radio control page 30
-
Programming automatic switch-off OPEN and CLOSED. With this function, the upper force limit of the drive
for OPEN and CLOSED movement has to be set to the smallest value sufficient enough to move the door
(pages 36 – 39)
-
Programming SOFT STOP CLOSED (page 54).
The factory setting for the Soft Stop Closed is 200 mm.
Select the fourth programming level. Change the Soft Stop Closed from 200 to 300mm per drive (level 3),
subsequently exit the programming level. Both drives have to be set to level 4 if the leaves are moved
separately, not synchronously (500 + 500mm)
-
Any other program level and steps should only be selected and changed in special cases.
Note:
Only use electric drives tested and released by the door manufacturer. Contact Tekla-Technik, Tor + Tür
GmbH & Co. KG for information about which drives have been tested and released for your requirements when
retrofitting a drive to a manually operated door.
(Also see 14. Declaration of Conformity)
Always observe the respective Schnetz installation instructions for doors with deadman drive type. ATS...WST
from Schnetz