Planning, Installation, Maintenance and Operating Instructions
dw
62-2 ME Sliding Doors
- 15 -
•
Standard Version
Fix the rope anchorage (1) to the last panel - viewed from the middle - using 2 M6x20mm bolts. The rope tension
pulley (2) is fixed to the last runner rail sleeve using its hexagon bolts (sleeve distance from edge of door is min.
400mm). The rope tension pulley (2) is located in front of the rope anchorage (1). The bracket (A) with the
hydraulic brake mechanism (3) is bolted tightly to the end of the runner rail using the M10x40mm hexagon bolts
and the clamp (C). Adjust the hydraulic brake mechanism so that the closing velocity does not exceed 0.2m/s or
fall below 0.08m/s. Tension the wire rope (4) via the spring-suspended tension pulley (2) until it can no longer slip.
The limit stops are adjustable hydraulic brake cylinders (end brakes (5+5a). For the position “door CLOSED“,
screw an end brake (5) into the bracket (B) 100/50/5, which has been previously fixed to the door leaf, using 4
M5x20mm bolts. The end brake comes up against the brackets (6) to be fixed to the runner rails – the brackets
are attached with clamps just like bracket (A). In the opening direction, the door comes up against the end brake
(5a) located in bracket (A). For larger doors, bolt a magnetic clamp (6) to bracket (A) using M4x10mm bolts. Fix
the magnetic clamp counterplate (6a) to the base plate on the rear door leaf using M4x8mm bolts. Weld or bolt
the base plate to the door leaf seal in advance. Use M8x30mm bolts for the latter option.
•
Shortened Stop
Fix the rope anchorage (1) to the last panel - viewed from the middle of each door leaf - using 2 M6x20mm bolts.
The rope tension pulley (2) is fixed to the last runner rail sleeve using its hexagon bolts (sleeve distance from
edge of door is min. 400mm). The rope tension pulley (2) is located in front of the rope anchorage (1). The
bracket (A) with the hydraulic brake mechanism (3) is bolted tightly to the end of the runner rail using the
M10x40mm hexagon bolts and the clamp (C). Adjust the hydraulic brake mechanism so that the closing velocity
does not exceed 0.2m/s or fall below 0.08m/s. Tension the wire rope (4) via the spring-suspended tension pulley
(2) until it can no longer slip.
The limit stops are adjustable hydraulic brake cylinders (end brakes (5+5a. For the position “door OPEN“, “door
CLOSED“, screw the end brakes (5+5a) into the bracket (B) 100/50/5 which has been previously fixed to the door
leaf using 4 M5x20mm bolts. The end brake comes up against the brackets (6) to be fixed to the runner rails – the
brackets are attached with clamps just like bracket (A). In the opening direction the end brake (5a) comes up
against the bracket (A).