background image

Made in Italy by

AUTOMATIC 

SWING DOORS  

U

S

E

R

 M

A

N

U

A

L

U

S

E

R

 M

A

N

U

A

L

GB

FOR PEDESTRIANS

English

Translation of the ORIGINAL INSTRUCTIONS

USER MANUAL - NEPTIS-16005_GB_Rel.1.0_04/2013 - CD0410GB

SLT-B
LET-B
SMT-B
SLT
LET
SMT

Neptis

Summary of Contents for Neptis LET

Page 1: ...taly by AUTOMATIC SWING DOORS USER MANUAL USER MANUAL GB FOR PEDESTRIANS English Translation of the ORIGINAL INSTRUCTIONS USER MANUAL NEPTIS 16005_GB_Rel 1 0_04 2013 CD0410GB SLT B LET B SMT B SLT LET SMT Neptis ...

Page 2: ...ing from changes to the system made without his prior consent When operating the system accident prevention regulations must be observed REMARKS Always meet the usage and maintenance conditions provided for by LABEL Maintenance and repair operations must only be performed by qualified and properly trained personnel PROPER BEHAVIOUR Only use the automatic door if it is in perfect technical conditio...

Page 3: ...TION IN NIGHT LOCK MODE 5 3 3 SUPPORT OPERATION FOR DISABLED PEOPLE 5 4 PROGRAM SELECTORS 6 4 1 MANUAL PROGRAM SELECTOR 6 4 2 EV MSEL MECHANICAL KEY SELECTOR 6 4 3 N DSEL DIGITAL PROGRAMMER USED LIKE PROGRAM SELECTOR 7 4 3 1 GENERAL PROGRAMMING MENU 9 4 3 2 PASSWORD 10 4 3 3 LANGUAGE 12 5 OPERATION IN CASE OF POWER SUPPLY FAILURE 13 6 NOTIFICATION OF ERRORS AND OPERATION PROBLEMS 14 7 MAINTENANCE ...

Page 4: ...ATOR ELECTRIC LOCK FLOOR STOP 8 9 1 7 5 6 4 3 8 1 2 POWER SUPPLY POWER MAXIMUM WEIGHT OF DOOR WING OPERATOR WITH BATTERY DIMENSIONS WORKING TEMPERATURE PROTECTION DEGREE ELECTRIC MOTOR POWER SUPPLY OF EXTERNAL ACCESSORIES 115 230Vac 10 50 60Hz 120W 120 Kg LET LET B 250 Kg SLT SLT B SMT SMT B 15 C 50 C IP31 24Vdc 24Vdc MODEL OPERATOR SLT B LET B SMT B SLT LET SMT 4 FREQUENCY OF USE continuous 550 x...

Page 5: ...he presence then once the pause delay has elapsed the door closes back t When the manual door opening button is pressed the door opens and stays open until the command remains active then once the pause delay has elapsed it closes back t If the electronic control unit has been programmed with the push e go function you can also open the door with a brief manual push t If the safety sensor in closi...

Page 6: ... if applicable Open door program The door stops in complete opening position The key can be taken out of the selector when in any position in order to prevent the work program from undesired changes Open door program The door stops in complete opening position Free manual door The automatic operation is disabled and door can be manually open Bi directional automatic program The door automatically ...

Page 7: ...ext one The operating programs to be selected by button are described below Bi directional automatic program The door automatically opens when each opening control activates Single direction automatic program output only To exclude the incoming detection on external radar input Single direction automatic program input only To exclude the outgoing detection on internal radar input Open door program...

Page 8: ...l single direction and open door automatic programs To deactivate pedestrian opening press again the button Deactivation of step by step operation if enabled in the setting of the operator Give a pulse to F2 button to deactivate the step by step operation and enable the door automatic closing Symbol F2 on display goes ON Press F2 button again to activate step by step operation Symbol F2 on display...

Page 9: ...ss to the use of N DSELdigital programmer F1 F1 F1 F1 5 UNUSED UNUSED F1 F1 F1 In the following sections explain how to manage user passwords and how to select the language LANGUAGE SECTION PASSWORD MANAGEMENT SECTION EXIT EXIT EXIT EXIT ENTER EXIT EXIT EXIT EXIT ENTER DIAGRAM 1 SECTION RESERVED FOR TECHNICAL SERVICE SECTION RESERVED FOR TECHNICAL SERVICE SECTION RESERVED FOR TECHNICAL SERVICE SEC...

Page 10: ...vice password is A A A A A To change the service password it is necessary to have access by primary password Use button to move the selection arrow downward F2 button to move the arrow upward HOW TO CHANGE THE PRIMARYPASSWORD Select PRIMARYPASSWORD Press OK F1 button To prevent changes in the work program of the door you can set a password that must be entered each time you act on the N DSEL progr...

Page 11: ...reverting to PASSWORD MANAGEMENT section The procedure needs to be carried out again Type the primary password Type the new service password selecting a combination of 5 characters from the lettersA B C D It is required to repeat the new password so type the previous combination again If the password typed is correct PASSWORD OK is shown on display for one second thus reverting to PASSWORD MANAGEM...

Page 12: ...WORD MANAGEMENTsection type PASSWORD ON OFF Press OK F1 button Press OFF F1 button to disable user password usage To return to general programming menu press the EXIT button twice From this moment on the access to N DSELdigital programmer as program selector is free Type the primary password Type the primary password 12 4 3 3 LANGUAGE To select the language do the following 1 Press the SET button ...

Page 13: ...oor in absence of main power supply is ensured by the battery Depending on the programming of the automation the door may operate as follows a Automatically open and stay open if the program selector is not set to Night Lock b The door stays closed but it can be opened by activating any opening command motion sensors buttons etc POWER SUPPLY LIGHT DISPLAY ON N DSEL PROGRAMMER Mains power supply on...

Page 14: ...ctor The door stops during the stroke and inverts the running direction The door detects an obstacle along its stroke Identify the obstacle and remove it The fixture experiences friction along its stroke Properly arrange the fixture for this operation please contact the service centre The electronic control units beeps multiple times and door operation is irregular The defect depends on the number...

Page 15: ...ce sensors taking care to lock the door while performing these operations 8 DISPOSAL At the end of its life this system must be disposed of in accordance with national provisions To this purpose we recommend that you contact specialised operators WARNING While uninstalling the operators with incorporated spring lock the spring using the special screw before removing the arm the spring pre tensioni...

Page 16: ...lariuzzi 17 A Tel 39 05 21 67 52 Fax 39 05 21 67 52 22 infocom labelspa it www labelspa com S Pancrazio P se 43126 PARMA ITALIA S p A AZIENDA CERTIFICATA SISTEMA QUALITA UNI EN ISO 9001 2000 Made in Italy by ...

Reviews: