27
iPOS4808 MX Technical Reference
2.5.4.
Environmental Characteristics
Min.
Typ.
Max.
Units
Size ( Length x Width x Height )
Global size
56 x 42 x 12.4
mm
~2.2 x 1.65 x 0.49
inch
Weight
20
g
Cleaning agents
Dry cleaning is recommended
Only Water- or Alcohol- based
Protection degree
According to IEC60529, UL508
IP00
-
2.5.5.
Logic Supply Input (+V
LOG
)
Min.
Typ.
Max.
Units
Supply voltage
Nominal values
9
36
V
DC
Absolute maximum values, drive operating
but outside guaranteed parameters
8
40
V
DC
Absolute maximum values, continuous
-0.6
42
V
DC
Absolute maximum values, surge
(duration
10ms)
†
-1
+45
V
Supply current
+V
LOG
= 7V
125
320
mA
+V
LOG
= 12V
85
220
+V
LOG
= 24V
50
145
+V
LOG
= 40V
40
120
2.5.6.
Motor Supply Input (+V
MOT
)
Min.
Typ.
Max.
Units
Supply voltage
Nominal values
11
50
V
DC
Absolute maximum values, drive operating
but outside guaranteed parameters
9
52
V
DC
Absolute maximum values, continuous
-0.6
54
V
DC
Absolute maximum values, surge
(duration
10ms)
†
-1
57
V
Supply current
Idle
1
5
mA
Operating
iPOS4808
-20
±8
+20
A
Absolute maximum value, short-
circuit condition (duration
10ms)
†
iPOS4808
26
A
Summary of Contents for iPOS4808 MX Series
Page 2: ......
Page 4: ......
Page 14: ... Technosoft 2014 XII iPOS4808 MX Technical Reference This page is empty ...
Page 37: ... Technosoft 2014 35 iPOS4808 MX Technical Reference ...
Page 69: ... Technosoft 2014 67 iPOS4808 MX Technical Reference Figure 3 23 Multiple Axis CAN network ...
Page 112: ... Technosoft 2014 110 iPOS4808 MX Technical Reference This page is empty ...
Page 113: ......
Page 114: ......