Technosoft 2014
43
iPOS4808 MX Technical Reference
3.4.6.
Operation Mode and Axis ID Selection
3.4.6.1
Selection Levels on Axis ID Inputs
On iPOS4808 the selection of the operation mode: CANopen or TMLCAN as also of the axis ID
number is done by setting different voltage levels on the inputs AxisID 0 (J1 pin 9), AxisID 1(J1 pin
11) and AxisID 2 (J1 pin 13). Each input can be set to one of the following 7 levels:
Level
Connection needed
L0
Connect input directly to ground
L1
Connect input through a 4.7K
Ω
resistor to ground
L2
Connected input through a 22K
Ω
resistor to ground
L3
Nothing connected
–
leave input open
L4
Connect input through a 22K
Ω
resistor to +5Vdc
L5
Connect input through a 4.7Kohm resistor to +5Vdc
L6
Connect input directly to +5V
The operation mode selection is done via AxisID 2:
CANopen mode, if the input levels are: L0, L1 or L2
TMLCAN mode, if the input levels are L3, L4, L5, L6
shows how to set the 7 levels on the AxisID 0 input and the resulting axis ID values
when AxisID 2 input level is set for
CANopen
values for axis ID in this mode of operation.
Remarks:
1. AxisID value is computed with formula: 49 x A 7 x A AxisID0, where each
AxisID can have one of the integer values: 0 to 6 (0 for L0, 1 for L1, 2 for L2, etc.)
2. If the resulting AxisID value is 0 (all 3 inputs are connected to GND), the axis ID will be set
to 127. If the resulting AxisID is greater than 127, the axis ID will be set to 255.
3. If the AxisID is set to 255, the drive remains
“non
-
configured”
waiting for a CANopen
master to configure it, using CiA-305 protocol.
A “non
-
configured” drive answers only to
CiA-305 commands. All other CANopen commands are ignored and transmission of all
other messages (including boot-up) is disabled.
The Ready (green) LED will flash at 1
second time intervals while in this mode.
shows how to set the 7 levels on the AxisID 0 input and the resulting axis ID values
when AxisID 2 input level is set for
TMLCAN
shows how to set all possible values for axis ID in this mode of operation.
Remarks:
1. AxisID is computed with formula: 49 x (AxisID2 - 3) + 7 x A AxisID0, where each
AxisID can have one of the integer values: 0 to 6 (0 for L0, 1 for L1, 2 for L2, etc.)
2.
If the resulting AxisID value is 0, the axis ID will be set to 255 and the drive will be in LSS
“non
-
configured” mode.
Summary of Contents for iPOS4808 MX Series
Page 2: ......
Page 4: ......
Page 14: ... Technosoft 2014 XII iPOS4808 MX Technical Reference This page is empty ...
Page 37: ... Technosoft 2014 35 iPOS4808 MX Technical Reference ...
Page 69: ... Technosoft 2014 67 iPOS4808 MX Technical Reference Figure 3 23 Multiple Axis CAN network ...
Page 112: ... Technosoft 2014 110 iPOS4808 MX Technical Reference This page is empty ...
Page 113: ......
Page 114: ......