Technosoft 2014
54
iPOS4808 MX Technical Reference
3.4.9.3
Recommendation for wiring
a) If the analogue signal source is single-ended, use a 2-wire twisted shielded cable as
follows: 1
st
wire connects the live signal to the drive input; 2
nd
wire connects the source
ground to the drive ground; shield will be connected to the drive ground terminal.
b) If the analogue signal source is differential and the signal source ground is isolated from
the drive GND, use a 2-wire twisted shielded cable as follows: 1
st
wire connects the
source plus (positive, in-phase) to the drive analogue input; 2
nd
wire connects the source
minus (negative, out-of-phase) to the drive ground (GND). Shield is connected only at the
drive side, to the drive GND, and is left unconnected at the source side.
c) If the analogue signal source is differential and the signal source ground is common with
the drive GND, use a 2-wire shielded cable as follows: 1
st
wire connects the source plus
(positive, in-phase) to the drive analogue input; 2
nd
wire connects the source ground to the
drive ground (GND); shield is connected only at the drive side, to the drive GND, and is
left unconnected at the source side. The source minus (negative, out-of-phase) output
remains unconnected.
3.4.10. Motor connections
3.4.10.1 Brushless Motor connection
Figure 3.10.
Brushless motor connection
Summary of Contents for iPOS4808 MX Series
Page 2: ......
Page 4: ......
Page 14: ... Technosoft 2014 XII iPOS4808 MX Technical Reference This page is empty ...
Page 37: ... Technosoft 2014 35 iPOS4808 MX Technical Reference ...
Page 69: ... Technosoft 2014 67 iPOS4808 MX Technical Reference Figure 3 23 Multiple Axis CAN network ...
Page 112: ... Technosoft 2014 110 iPOS4808 MX Technical Reference This page is empty ...
Page 113: ......
Page 114: ......