Technosoft 2014
31
iPOS4808 MX Technical Reference
2.5.12. Linear Hall Inputs (LH1, LH2, LH3)
Min.
Typ.
Max.
Units
Input voltage
Operational range
0
0.5÷4.5
4.9
V
Absolute maximum values, continuous
-7
+7
Absolute maximum, surge (duration
1S)
†
-11
+14
Input current
Input voltage 0…+5V
-1
±0.9
+1
mA
Interpolation Resolution
Depending on software settings
11
bits
Frequency
0
1
KHz
ESD protection
Human body model
±1
KV
2.5.13. Sin-Cos Encoder Inputs (Sin+, Sin-, Cos+, Cos-)
Min.
Typ.
Max.
Units
Input voltage, differential
Sin+ to Sin-, Cos+ to Cos-
1
1.25
V
PP
Input voltage, any pin to GND
Operational range
-1
2.5
4
V
Absolute maximum values, continuous
-7
+7
Absolute maximum, surge (duration
1S)
†
-11
+14
Input impedance
Differential, Sin+ to Sin-, Cos+ to Cos-
1
4.2
4.7
K
Ω
Common-mode, to GND
2.2
K
Ω
Interpolation Resolution
Software selectable, for one sine/cosine
period
2
10
bits
Frequency
Sin-Cos interpolation
0
450
KHz
Quadrature, no interpolation
0
10
MHz
ESD protection
Human body model
±1
KV
1
For many applications, an 120
Ω
termination resistor should be connected across SIN+ to SIN-, and across COS+ to
COS-. Please consult the feedback device datasheet for confirmation.
Summary of Contents for iPOS4808 MX Series
Page 2: ......
Page 4: ......
Page 14: ... Technosoft 2014 XII iPOS4808 MX Technical Reference This page is empty ...
Page 37: ... Technosoft 2014 35 iPOS4808 MX Technical Reference ...
Page 69: ... Technosoft 2014 67 iPOS4808 MX Technical Reference Figure 3 23 Multiple Axis CAN network ...
Page 112: ... Technosoft 2014 110 iPOS4808 MX Technical Reference This page is empty ...
Page 113: ......
Page 114: ......