VARIO : Service & maintenance manual- rev. 4.2
Page 9.16
9.3.3.3.
Default Setting
To load the default parameter values, scroll using the
+/-
effort level keys until the display shows:
DEFAULT SETTING ?
Press
ENTER.
display shows:
CONFIRM ?
press
ENTER
to write the default values to the low kit, and return to the upper menu level by
pressing
CLEAR
for a few seconds.
To write these parameters to the low kit, use the “Write to low kit” function.
9.3.3.4.
Table of configuration parameters:
Id
(Par.)
Units
Name
Description
LED
powered
Self-
powered
1
decimal
[Rt]
Transmission Ratio
140
140
2
[Rvel]
Speed ratio
1
1
3
mA
[Im]
Minimum braking
0
0
4
W
[Pmc]
Constant maximum power
200
200
5
in cent
[Km]
Power factor correction (constant torque)
100
100
6
0.1N
[Ca]
User friction torque
40
40
7
°C
[Tea]
Maximum temperature on the coil
125
125
8
User
Rpm
[RPMmin]
Minimum user SPM
(start cut braking ramp)
35
35
9
Type/sec [RpmF1]
Flywheel target RPM speed in standby
(and power-on speed for self powered)
1
1
10
User Rpm [RpmF2]
Rpm filter threshold
75
75
11
[Rvel]
Speed ratio (decimal part)
60
60
12
0.1N
[D_Ca]
User delta friction torque
10
10
13
-
-
Enable flag for registers at address ≥ 100
-
-
Summary of Contents for Vario Excite + 500
Page 1: ...V VA AR RI IO O E X C I T E REV 4 2...
Page 2: ......
Page 4: ......
Page 10: ...VARIO Excite Service maintenance manual rev 4 2 Page vi Page intentionally left blank...
Page 58: ...VARIO Excite Service maintenance manual rev 4 2 Page 5 6 Page intentionally left blank...
Page 170: ...VARIO Excite Service maintenance manual rev 4 2 Page 7 70 Page intentionally left blank...
Page 206: ...VARIO Excite Service maintenance manual rev 4 2 Page 9 26 Page intentionally left blank...
Page 208: ...VARIO Excite Service maintenance manual rev 4 2 Page 10 2 Page intentionally left blank...
Page 219: ......