RECLINE EXCITE: Service & Maintenance Manual - rev. 2.4
9.7. TOUCH SCREEN CALIBRATION
To access the calibration procedure, press the
0369
keys when the machine is in stand by, the keys
must be pressed one after the other. The following message appears on the LCD display:
ENTER PASSWORD:
To access the procedure, type in the password
2409
and press
ENTER
to confirm. At this point the
machine display will appear as follows, with the message
“To calibrate tap the 3 crosses which
appear in sequence”
scrolling once along the top, followed by the message
“Tap the centre of the
cross to continue the calibration, or tap any other point to cancel and exit”
until the user either
initiates the procedure or exits:
Tap the centre of the + which appears on the screen, using an object that is pointed but not sharp.
The procedure must be repeated three times, with the + appearing in three different positions.
At the end, the message
“Calibration successful”
will appear if the procedure was correctly
carried out, or
“Calibration incomplete”
if the procedure was not completed properly, after which
the machine reverts to standby mode.
Page 9.31
Summary of Contents for Recline 500
Page 1: ...SERVICE MAINTENANCE MANUAL REV 2 4...
Page 2: ......
Page 4: ......
Page 10: ...RECLINE EXCITE Service Maintenance Manual rev 2 4 Page vi Page intentionally left blank...
Page 46: ...RECLINE EXCITE Service Maintenance Manual rev 2 4 Page 3 14 Page intentionally left blank...
Page 58: ...RECLINE EXCITE Service Maintenance Manual rev 2 4 Page 4 12 Page intentionally left blank...
Page 94: ...RECLINE EXCITE Service Maintenance Manual rev 2 4 Page 6 34 Page intentionally left blank...
Page 134: ...RECLINE EXCITE Service Maintenance Manual rev 2 4 Page 7 40 Page intentionally left blank...
Page 140: ...RECLINE EXCITE Service Maintenance Manual rev 2 4 Page 8 6 Page intentionally left blank...
Page 172: ...RECLINE EXCITE Service Maintenance Manual rev 2 4 Page 9 32 Page intentionally left blank...
Page 181: ......