13.5
Software Upgrade
During a COM46 software upgrade sequence the card will upload the new image from the IP
address set in the ‘Server_IP_Address’ field for a software upgrade.
The new SW image is then tested to verify it is a valid COM46 image and finally written to the
card’s flash memory. Normal operation of the cards continues during this part of the upgrade
although the LEDs will begin to flash the “SW Upgrade” message pattern while the flash is
being reprogrammed.
DO NOT turn off power or unplug a card that is updating its SW image. YOU WILL
create a doorstop.
During the upgrade process, the status can be determined by evaluating the LED states
according to figure 70 below.
LED Behavior
State
Approx.
duration
1
2
3
4
5
6
7
8
9
Note
ON
ON
ON
ON
ON
ON
ON
ON
ON
Tuners locked,
video streaming
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
FLASH
Flash
programming
2
– 3 min
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
Intialization
10 sec
See Startup Behavior
Table 4
Note: The PWR LED may flash briefly at the start and/or end of the upgrade.
If you see a behavior not described above in conjunction with a failure to complete the update,
it may be an indication that something has gone wrong with the update. You should check that
you are following each of these guidelines before attempting another update.
All system/PC connections are functioning correctly.
The Software has been correctly uploaded to a COM46 card’s TFTP utility.
The TFTP server is running on the PC handling the update.
The TFTP server is fully configured and pointing to the folder containing the update.
Figure 74 - LED Behavior during Software Upgrade