MediaGateway
User Manual
60
Link quality
: The “link quality” is an indicator about the signal integrity of the 100BASE-
T1 link on this port. 1 = Poor , 5 = Excellent. For more information about link quality and
its measurement, please contact Broadcom directly.
802.1AS mode
:
For each port following values can be set:
DISABLED
: Port will not take part of any 802.1AS traffic
BRIDGEX_MASTER
: Port will take part of 802.1AS network as PTP-Bridge-
Master.
BRIDGEX_SLAVE
: Only one Slave per BridgeX is allowed. MediaGateway will
take part of 802.1AS network as PTP-BridgeX-Slave
MASTER_802.1AS
: Port will work as 802.1AS Master Clock. Only one
MasterClock per switch is possible.
For further information, please see
C
Test Mode
: For 100BASE-T1 Ports it is possible to set a BroadR-Reach Physical Layer
Test Mode. There are five test modes defined in the BroadR-Reach Specification to
check the compliance of a port.
Warning
: If a test mode has been selected there is no communication possible for this
port.
Important
: In case of BroadR-Reach Master test, it is mandatory to restart the switch
to recover link.
Note
: For compliance testing an oscilloscope with special test software is necessary.
Drop ingress packets with…
:
Source IP
: one IP address can be configured here. It is a filter for incoming traffic. Data
with configured IP address as source IP address will be dropped and not forwarded,
when incoming on this port.
Destination IP
: one IP address can be configured here. It is a filter for incoming traffic.
Data with configured IP address as destination IP address will be dropped and not
forwarded.
Redirect packets to…
: By defining an Ethernet port (or the SFP-slot) you can redirect
packets with a specific destination IP address to this port, independent from any other
configuration. It means that the packet is not sent to the port it was originally supposed
to be sent. This function is only available for IP layer.