MediaGateway
User Manual
57
o
leave without VLAN if received without VLAN on another port
Remove
: a frame leaves the switch on this port without the VLAN
Normalized
: a frame leaves the switch on this port with the VLAN
Tx octets
: decimal value of sent octets on this port.
Rx octets
: decimal value of received octets on this port.
Prevent Sleep Port
: This option is available if the function “Prevent sleep” on “Control
panel” tab is deactivated.
This port is monitored: If there is incoming traffic on this port, the
MediaGateway doesn’t fall asleep.
This port is not monitored: The MediaGateway can fall asleep, even if there is
incoming traffic on this port.
Mirroring
: On each switch only on port can be a mirroring port. Please select the ports
to be mirrored.
Note:
This is only valid for one switch! For example, if you want to mirror incoming
traffic on S3-P3 to S1-P5, it is necessary to mirror the traffic on S3-P4, then S2-P4 and
then on S1-P5.
Drop ingress packets with…
:
Inner VLAN IDs
: as many as wished values between 0x1 and 0xFFF can be defined
separated by “,” [E.g.: 100, 101, EDF, …]. It is a filter for incoming traffic. Data with
configured innerVLAN-ID will be dropped and not forwarded, when incoming on this
port.
Source IP
: one IP address can be configured here. It is a filter for incoming traffic. Data
with configured IP address as source IP address will be dropped and not forwarded,
when incoming on this port.
Destination IP
: one IP address can be configured here. It is a filter for incoming traffic.
Data with configured IP address as destination IP address will be dropped and not
forwarded.
Drop mirrored packets with…
:
Each field allows one MAC address. In total
six MAC addresses can be configured. It is a
filter for outgoing traffic. Data with