1-4
INTRODUCTION
Model 810, 812, 820, 822, 828 Series
Introduction
1
General Installation Instructions
The following are general installation instructions. For
complete installation details, please see the checkout
card.
Site Preparation
Review the area where the machine is to be installed
before uncrating the machine. Make sure all possible
hazards to the user and the equipment have been
addressed.
For Indoor Use Only:
This machine is designed to
operate indoors, under normal ambient temperatures of
70°F to 75°F (21°C to 24°C). The machine has
successfully performed in high ambient temperatures of
104°F (40°C) at reduced capacities.
CAUTION!
This machine must be installed on
a level surface to avoid the hazard of tipping. Extreme
care should be taken in moving this machine for any
reason. Two or more people are required to safely move
this machine. Failure to comply may result in personal
injury or equipment damage.
When uncrating the machine, inspect the machine for
damage. Report any damage to your Taylor distributor.
This machine is made in the USA and has USA sizes of
hardware. All metric conversions are approximate and
vary in size.
Electrical Connections
The grill has two electrical connections. Check the data
plate on the grill for voltage, cycle, phase, and electrical
specifications. The power connections are located
behind the access line cover on the rear of the control
box under the front staging side of the grill.
In the United States, this equipment is intended to be
installed in accordance with the National Electrical Code
(NEC), ANSI/NFPA 70-1987. The purpose of the NEC
code is the practical safeguarding of persons and
property from hazards arising from the use of electricity.
This code contains provisions considered necessary for
safety. Compliance therewith and proper maintenance
will result in an installation essentially free from hazard.
In all other areas of the world, equipment should be
installed in accordance with the existing local codes.
Please contact your local authorities.
The proper wire size and fused circuit should be selected
according to grill data label information. Incoming power
must be connected to the terminals with black characters
on a white background.
WARNING!
This machine must be properly
grounded!
DO NOT
operate this machine unless it is
properly grounded and all service panels and access
doors are restrained with screws. Failure to do so can
result in severe personal injury from electrical shock!
IMPORTANT!
This machine is provided with a
grounding lug that is to be properly attached to the rear of
the frame by the authorized installer. The installation
location is marked by the equipotential bonding symbol
(5021 of IEC 60417-1) on the removable panel and the
frame.
NOTICE!
Machines that are permanently
connected to fixed wiring and for which leakage currents
may exceed 10 mA, particularly when disconnected, not
used for long periods, or during initial installation, shall
have protective devices, such as a GFI, to protect against
the leakage of current, installed by the authorized
personnel to the local codes.
NOTICE!
Stationary machines which are not
equipped with a power cord and a plug or another device
to disconnect the appliance from the power source must
have an all-pole disconnecting device with a contact gap
of at least 0.12 in. (3 mm) installed in the external
installation.