ENGLISH
2
Draining dirty water
Model
P1=330W
P1=500W
Electrical data
P1 Rated absorbed power [W]
330
500
P2 [W]
160
240
USA P2 [HP] Fractional (decimal)
1/5 (0.2)
1/4 (0.25)
Mains voltage [V]
~ 115-120V AC
Mains frequency [Hz]
60
Current [A]
3.0
4.8
Capacitor [µF]
12.5
20.0
Capacitor [Vc]
450
250
Hydraulic data
Max. flow rate [gpm]
33.9
49.3
Max. head [ft]
17.4
23.0
Max. head [psi]
7.7
10.2
Max. immersion depth [ft]
23
Min. AUT starting height [in]
10.2
Min/max. stopping height [ft]
3.9/5.9
Residual water height [in]
0.4
Type of cable
SJTOW 18AWG
Grade of motor protection
IP X8 / NEMA 6P
Insulation class
F
Liquid temperature range [F]
according to EN 60335-2-41 for domestic use
+32 F / +95 F
Max. particle dimension [in]
1.125
Max. ambient temperature [F]
104
Weight
DNM NPT
1'' 1/4 F
Table 2
The pump which does not stand on a base cannot support the weight of the pipes, which must be
supported in some other way.
4. MANAGEMENT
4.1 Storage
All the pumps must be stored in a dry covered place, with possible constant air humidity, free from vibrations and dust.
They are supplied in their original pack in which they must remain until the time of installation.
4.2 Transport
Avoid subjecting the products to needless impacts and collisions.
4.3 Weight
and
dimensions
The adhesive plate on the packaging indicates the total weight of the pump and its dimensions.
5. WARNINGS
The pumps must never be carried, lifted or allowed to operate suspended from the power cable; use
the handle provided.
The pump must never be allowed to run when dry.
On the body there is a venting hole to avoid phenomena of cavitation when starting the pump.
It is therefore normal
for a small amount of water to come out of the pump during operation. (Fig.1).
The sealing device contains lubricant which is non-toxic but which may alter the characteristics of the water, in the
case of pure water, if the pump were to have any leaks.
6. INSTALLATION
The electrical system must be compliant with local norms.
Screw on the elbow with hosetail fitting provided in the packaging. For the dirty water version only the fitting for 30 mm
(1.18”) pipes; if you want to use a pipe with a larger diameter, change the elbow coupling. Use a pipe tightening clamp to
secure the pipe to the fitting.
It is advisable to use pipes having an internal diameter of 30 mm (1.18”) to avoid the decrease of pump performance
and the possibility of blocking.
If the bottom of the trap where the pump is to be placed is particularly dirty, a raised support should be provided so as
to avoid blocking of the suction grid (Fig.2)
Totally immerse the pump in the water.
Ensure that the minimum dimensions of the trap in which it is housed are as follows:
Min. base dimensions (mm) 460x460 (18.11”x18.11”) / Min. height (mm) 400 (15.75”)