TALEX Sp. z o.o.
ul. Dworcowa 9C
77-141 Borzytuchom
tel. +48 59 821 13 40
e-mail.
User manual
OptiCUT disc mower
Page
33
of
59
Top view
Bottom view
Rys.22. Cutter bar – oil check: A – filler, oil level control
B – oil drain
Oil in the cutter bar should be changed immediately after work, while the oil is still hot. In order
to do that, the following must be done:
-
Open the oil filler, control plug (A) Fig. 18
-
Lift the bar
-
Open the oil drain plug (B)
-
Drain the oil to the prepared container
-
Close the oil drain plug (B)
-
Lower the cutting bar to the horizontal level and fill in the SAE90EP oil (in
accordance with the quantity indicated in the Table nr 1)
The oil in the bevel gear and the cutting bar should be changed after the first 50
hours of operation. The following oil change should be performed after 500
operating hours or every year.
If leaking is noticed, the sealing and the oil level should be checked, operating the mower
with low oil levels may cause permanent damage to the mower. All repairs of the cutting
bar and the gear may be performed by the indicated by the manufacturer mechanical
workshop.
DANGER
If the level of oil in the bar is too high, it may worsen its functioning or even
damage it.