K - 2
K - 2
Air Conditioner
31
W701-0220E
A/C system
trouble
phenomenon
Status explanation
of A/C system
pressure
Phenomenon explanation to
consider other factors
Diagnosis result (phenomenon of
principal cause)
Possible cause
Measures (specific
part name and
repair method)
----------------
Evaporator is frosting. Thermistor
is not cold. If louver blowing
temperature gets cold enough,
compressor will be OFF tentatively.
Installation position failure of
thermo therms sensor
(thermistor and mechanical
thermo capillary).
Check that thermo
therms sensor is in
proper position.
Move it to proper
position in case of
NG.
----------------
Blowing air volume changes
gradually. When A/C is OFF, and
blower is ON, much water is
drained from drain hose.
Evaporator is frosting. Thermistor
is cold. If louver blowing
temperature gets cold enough,
compressor will not be OFF.
Thermistor or thermo amp.
failure (will not turn OFF).
Check thermo
system wiring, or
replace parts.
----------------
Gas leakage from
evaporator case.
Seal with repair
tape or packing
agent.
----------------
Air volume is small from the
beginning.
Evaporator frost formation.
Gas leakage from joint of
heater unit and evaporator
unit.
Affix packing
again.
Insufficient
cooling. (Normal
cooling at
beginning, and
gradually reduce
cooling later.)
----------------
Air volume does not decrease.
Freezing of TXV
Water intrusion in circuit.
Deflate from circuit
and fill refrigerant.
------------------------------------
Outside air intrusions to
inside, though inside
circulation.
Adjust inside and
outside air switch
dumper.
-------------------------------------
Warmed with heater. (Water
valve adjustment failure or
leakage, and air mix dumper
does not close completely.)
Check and adjust
water valve and air
mix dumper.
Blowing temperature is high and it
does not get cold (refrigeration
circuit is normal).
-------------------------------------
Thermostat operating
temperature failure.
Check thermostat.
(Check mechanical
thermo, thermistor,
thermo amp., and
thermo VR.)
-------------------------------------
Blocking of evaporator fin.
Wash or replace
evaporator.
Blower motor revolution is
slow.
Check and replace
blower motor.
Insufficient
cooling.
Normal
Air volume is few and does not get
cold, though blowing temperature is
cold.
-------------------------------------
Blocking of blower
inhalation vent.
Check and repair.
Summary of Contents for TR-800XXL4
Page 47: ...B 9 B 9 Rotary Joint 27 W181 0440E Upper view A Lower view B...
Page 119: ...F 1 F 1 Winch System 1 WF02 0251E F 1 Winch System 1 General Hydraulic Circuit for Winch...
Page 135: ...G 1 G 1 Telescoping System 3 WG02 0321E Telescoping cylinder at select...
Page 143: ...G 2 G 2 Boom Five Section Boom G 2 11 W536 0761E 11...
Page 196: ...13 13 W701 0220E K 2 K 2 Air Conditioner K 2 4 Layout 4 1 Overall layout 4 345 107 61000...
Page 197: ...14 14 W701 0220E K 2 K 2 Air Conditioner K 2 4 2 Overall layout 0 345 110 73000...
Page 198: ...15 15 W701 0220E K 2 K 2 Air Conditioner K 2 4 3 Evaporator section 5 345 107 02000...
Page 199: ...16 W701 0220E K 2 K 2 Air Conditioner 5 Compressor Assy...
Page 200: ...17 17 W701 0220E K 2 K 2 Air Conditioner K 2 6 Evaporator Assy...
Page 201: ...18 18 W701 0220E K 2 K 2 Air Conditioner K 2 7 Condenser Assy...
Page 202: ...19 19 W701 0220E K 2 K 2 Air Conditioner K 2 8 Electric 8 1 Electric circuit 0 363 205 60030...
Page 203: ...20 20 W701 0220E K 2 K 2 Air Conditioner K 2 8 2 Main harness A...
Page 204: ...21 21 W701 0220E K 2 K 2 Air Conditioner K 2 8 3 Main harness B...
Page 222: ...39 K 2 K 2 K 2 Air Conditioner 39 W701 0220E 12 2Compressor diagnosis chart 1 2...
Page 223: ...40 K 2 K 2 K 2 Air Conditioner 40 W701 0220E Compressor diagnosis chart 2 2...
Page 224: ...K 2 K 2 Air Conditioner 41 W701 0220E 13 Troubleshooting...
Page 225: ...K 2 K 2 Air Conditioner 42 W701 0220E...
Page 226: ...K 2 K 2 Air Conditioner 43 W701 0220E...
Page 227: ...K 2 K 2 Air Conditioner 44 W701 0220E...
Page 228: ...K 2 K 2 Air Conditioner 45 W701 0220E...
Page 229: ...K 2 K 2 Air Conditioner 46 W701 0220E...
Page 237: ...L 1 L 1 Control System 2 WL02 0090E 2 General of pneumatic control devices Pneumatic Circuit...
Page 291: ...T 5 T 5 Air Dryer 26 W232 0032E Heater View A 39 C B B A 58 59 2 IW232 0030E03...
Page 370: ...8 8 WZ03 3300E Z 5 Z 5 Electric Circuit MDT Carrier Upper Z 5 IWZ03 3300E01...
Page 372: ...10 Z 6 Z 6 Electric Circuit MDT Carrier Lower Z 6 10 WZ03 3310E IWZ03 3310E01...
Page 400: ...38 Z 24 Z 24 Harness Lower Sub 38 WZ04 2450E Z 24 Z 24 Harness Lower Sub 2 349 310 00200...