Danger due to electric current                        

Danger by dangerous, electric voltage! Death or severe injury can occur if the corresponding 
precautions are not taken!

Information

Important additional information and advice for user.

2.3

Product safety

The device conforms to the state of the art at the time of delivery and is fundamentally considered to 
be reliable. The device and its accessories must only be used in a 

awless condition and installed and 

operated in compliance with the assembly instructions and/or operating instructions. Operating out-
side the device's technical speci

cations (

  name plate and attachment / technical data) can lead to 

a defect in the device and additional damage!

In the case of a malfunction or a failure of the equipment check all functions with alarms in 
order to prevent injury to persons or property. Note possibility of back-up operation. If used in 
intensive animal environments, any malfunctions in the air supply must be detected as soon 
as possible to prevent the development of a life-threatening situation for the animals. The 
design and installation of the system must comply with local regulations and directives. In 
Germany these include DIN VDE 0100, the animal protection and the keeping of working 
animals ordinance and the pig-keeping ordinance etc. Also note the instructions of AEL, DLG, 
VdS. 

2.4

Requirements placed on the personnel / due diligence

Persons entrusted with the planning, installation, commissioning and maintenance and servicing in 
connection with the frequency inverter must have the corresponding quali

cations and skills for these 

jobs.
In addition, they must be knowledgeable about the safety regulations, EU directives, rules for the 
prevention of accidents and the corresponding national as well as regional and in-house regulations. 
Personnel to be trained or instructed and apprentices are only permitted to work on the device under 
the supervision of an experienced person. This also applies to personnel undergoing general training. 
Comply with the legal minimum age. 
This device is not intended to be used by people (including children) who have restricted mental, 
sensory or intellectual abilities or who have a lack of experience and/or knowledge. 

2.5

Start-up and during operation

Attention!

During commissioning, unexpected and hazardous conditions can arise in the entire installation 
due to defective adjustments, defective components or incorrect electrical connections. Remove all 
persons and objects from the hazardous area.

During operation, the device must be closed or installed in a control cabinet. Fuses may only be 
replaced by new ones and must not be repaired or bypassed. The data for the maximum line fuse 
are to be considered absolutely (

 Technical data). Use only fuses speci

ed in schematic dia-

grams.

Any faults detected in the electric system/modules/operating equipment must be corrected immedi-
ately. If these faults are not corrected, the device/system is potentially very dangerous. The 
device/system must therefore not be operated when it is faulty.

Pay attention to smooth, low vibration running of the motor/fan, the appropriate instructions in the 
drive documentation must be observed!

2.6

Working on device / Hazards through 

residual voltage

Information

Mounting, electrical connection, and start-up operation may only be carried out by an electrical 
specialist in accordance with electrotechnical regulations (e.g. EN 50110 or EN 60204)!

Operating Instructions 

FRQ5S-E-6/10A

Safety instructions

L-BAL-E247-GB 1512 Index 001

Part.-No. 00163444-42

5/17

Summary of Contents for FRQ5S-E-10A

Page 1: ...with sine lter for 1 fans Operating Instructions Speed controller with 5 step switch for presetting the fan speed Keep for reference Software version D1628A from Version 11 03 L BAL E247 GB 1512 Index...

Page 2: ...tdoor installation 8 4 4 Installation location for agriculture 9 4 5 Temperature in uences during commissioning 9 5 Electrical installation 9 5 1 Safety precautions 9 5 2 EMC compatible installation 9...

Page 3: ...ical data 14 8 1 1 Max load dependent on ambient temperature and line voltage 15 8 2 Connection diagram 16 8 3 Dimensions mm 16 8 4 Manufacturer reference 17 Operating Instructions FRQ5S E 6 10A L BAL...

Page 4: ...consequence of unauthorized repairs or modi cations 1 4 Copyright These operating instructions contain copyright protected information The operating instructions may be neither completely nor partiall...

Page 5: ...directives rules for the prevention of accidents and the corresponding national as well as regional and in house regulations Personnel to be trained or instructed and apprentices are only permitted to...

Page 6: ...ufacturer s original spare parts wearing parts accessories These parts are specially designed for this device If parts from other sources are used there is no guarantee that they are designed and prod...

Page 7: ...tep 5 to step 0 is not possible 0 1 2 3 4 5 0 Hz 10 Hz 20 Hz 30 Hz 40 Hz 50 Hz 23 05 2013 v_5_step_icontr_basic_sa vsd The output frequency can be adapted by an internal potentiometer if necessary inv...

Page 8: ...an be easily accessed Depending on the housing model cut off necessary cable inlets respectively to the cable diameter Or alternative use cable inlet for cable glands Metal sheet housings are supplied...

Page 9: ...the device Disregarding this regulation can lead to severe personal injury For metal cable inlets the necessary protective earth connection to the bottom of the housing is made by screws The device ma...

Page 10: ...between two outer conductors all current sensitive fault current circuit breakers must be used EN 50 178 Art 5 2 5 5 Inverter output 5 5 1 Motor connection The motor leads are connected to the termin...

Page 11: ...at certain frequencies Potemtiometer adjustable with a screwdriver Left stop No reduction i e output frequency e g in step 5 50 Hz factory setting diagram Right stop Maximum reduction 25 i e output fr...

Page 12: ...tion below 3 Hz switch off by the enable switch off of line voltage or in case of a fault the relay de energizes 5 9 Bypass circuit Please observe the following during bypass switching controller shun...

Page 13: ...tion above 5 Hz terminals 21 24 bridged De energized at modula tion below 3 Hz 21 22 bridged Temperature management active The device has an active temperature management to protect it from damage due...

Page 14: ...at the output 2 At rated voltage cos 0 8 at the output values for different speci cations on request 3 Max supply side line fuse according to DIN EN 60204 1 classi cation VDE0113 chapter 1 Line voltag...

Page 15: ...pendent on ambient temperature and line voltage The maximum permissible temperature for the rated current at rated voltage is speci ed as rated temperature Since the dissipation of the power loss heat...

Page 16: ...ernal thermostats 2 TB 1 Kontaktbelastung Contact rating max AC 250 V 2 A 5 3 UMPO09K13 17 03 2015 FRQ5S E 6 10A 22 24 21 BU RD BK 0 1 2 3 5 4 1 Line 1 208 277 V 50 60 Hz 2 1 Motor with internal therm...

Page 17: ...ve any questions concerning the use of our products or plan special uses please contact Systemair Industriev gen 3 73930 Skinnskatteberg Telefon 46 0 222 440 00 Telefax 46 0 222 440 99 mailbox systema...

Reviews: