40
o.
The
conditions
of
stability
during
use,
transportation,
assembly,
dismantling
when
out
of
service
The
unit
must
always
be
handled
in
an
upright
position.
Never
tilt
any
section
more
than
15
degrees.
If
sections
must
be
tilted
more
than
15
degrees,
sections
with
fans
or
rotating
exchangers
that
can
be
drawn
out
for
service
must
be
secured
carefully.
During
transportation,
installation,
dismantling
or
other
handling,
it
must
be
secured
that
all
components
in
the
unit
are
properly
fastened
and
with
additional
attention
to
the
control
of
anti
‐
vibration
mounts
under
the
fans
that
they
are
undamaged.
The
mounting
and
smooth
running
of
the
fans
must
be
controlled
and
handled
with
great
care.
o.1
Installed
reliable
to
avoid
units
to
be
tilted
or
moved
by
the
any
storm.
Units
installed
on
roofs
and
other
places
with
the
risk
of
heavy
winds
must
be
installed
reliable
to
avoid
that
they
can
be
tilted
or
moved
by
the
any
storm.
The
base
frame
is
provided
with
holes
that
are
intended
for
fastening
by
sufficient
bolts
and
fittings
supplied
by
the
installer.
o.2
Transport
of
section
with
heat
pump
unit
During
transportation,
the
unit
section
–
DVU
‐
must
always
be
in
the
upright
position
or
tilted
less
than
30
˚
.
If
it
is
necessary
to
tilt
the
unit
more
than
30
˚
,
the
suction
pipe
of
the
compressor
must
point
upwards
to
prevent
the
escape
of
oil
from
the
compressor
sump.
o.3
Disposal
of
the
heat
pump
system
‐
type
DVU
Prior
to
the
disposal
of
the
DVU
unit
section,
the
refrigerant
in
the
heat
pump
system
must
be
drained
off
by
a
skilled
technician
from
a
certified
company.
After
correct
evacuation
of
the
refrigerant,
the
disposal
of
the
DVU
unit
section
is
similar
to
the
disposal
of
the
rest
of
the
air
handling
unit.
o.4
Generel
disassembly
–
sharp
edges
Pay
attention
to
several
sharp
edges
during
dismantling
and
disposal
of
the
unit.
To
avoid
injury,
CE
‐
marked
cut
‐
resistant
gloves
as
well
as
helmet
must
be
used.
The
measures
are
described
further
in
the
Maintenance,
Dismantling
and
Disposal
Manual.
p.
Instructions
for
machinery
where
these
are
regularly
to
be
transported
The
subject
in
the
Machinery
Directive
about
machinery
that
are
regularly
to
be
transported
does
not
exist
for
the
DV
air
handling
units,
because
those
units
are
for
specially
made
for
one
intended
application.
q.
The
operating
method
to
be
followed
in
the
event
of
breakdown.
Safe
restart.
Use
the
below
mentioned
procedure
in
the
event
of
breakdown
or
blockage:
Switch
off
the
power
and
lock
the
automatic
circuit
breaker
by
padlocks
in
the
off
position.
Remove
the
reason
for
breakdown
or
blockage.
Follow
the
start
‐
up
procedure
described
in
section
k.
Summary of Contents for Danvent DV-10
Page 16: ...15 DVE Plug fan DVD Silencer DVX Humidifier...
Page 57: ...56...
Page 84: ...8 8...
Page 88: ...9 4 9 1 3 Information about connection of cables to terminals on the control board...
Page 91: ...9 7...
Page 103: ...9 19...
Page 111: ...12 3...
Page 115: ...12 7 Frequency converter is always necessary for the control of each PM motor...
Page 119: ...13 1 Annex 13 Commissioning See separate cover with annexes 1 2 3 and 13...