34
1.6.13 SCAN KEY
Starts scanning of 1 to n channels (n being defined as indicated below), compares each measurement with its
assigned tolerance and displays the results with a global indication : part OK (green light), rework (yellow light), or
reject (red light). This information is also transmitted to the opto-coupler (refer to section 1.8.3).
It is also possible to configure the external contact (foot pedal) for scanning.
Scanning mode requires the connection of one or more multi-channel units
D102
or
D108
(for probes) or
D104
(for
RS232 instruments (refer to sections 2.3 and 3.3).
How to use the scanning mode :
1/ connect the
D100S
unit with one or more
D102/108/D104
. If required, connect a foot pedal or another external
contact to start scanning. A pneumatic unit D110 or D110V vacuum can also be used for lifting the probes.
2/ Press
Setup
key 3/ then
Scan
key
4/ Enter the number of the first channel to be scanned (1 to 63).
5/ Enter the number of the last channel to be scanned (1 to 64).
6/ If necessary, enter the channel number on which to stop (e.g. opportunity to move the workpiece). Pressing Enter
or foot pedal (whatever its function) will continue the scanning. If no stop is required, just press ENTER (stop
channel = last channel).
7/ If required, assign the function of the external to start the scanning, combined as required with data transmission
or store and/or with probe lifting, then enter delay time between external contact and start scanning (explained
with Set Up function in section 1.6.11)
8/ If the data is to be stored, the number of channels to be stored must be entered in
Setup
–
Store
then 5 (
refer to
section 1.6.15
).
9/ If required, enter Min/Max mode for any channels. Scanning automatically stops when a given channel is in
Min/Max mode and waits for measurement. To continue scanning, simply press the
Enter
key or
foot pedal
.
10/ Enter the channels working in the A +/- B or A+/- function (do not forget the correct direction sign) the diameter
or any multiplication factor function, allocation of a probe to several channels (
refer to section 1.6.3
)
Example : channel 1 - 6
channel 2 - 7
channel 3 + 8
channel 4 minimum measurement
channel 5 diameter measurement
5 channels have to be scanned, of which 3 in A +/- B.
11/Choose the resolution of the display. The lower the resolution, the faster the scanning will be :
using 0.0001 mm / 0.00001 in :
approx. 2 measurements / sec.
using 0.001 mm / 0.0001 in : approx. 4 measurements / sec.
using 0.01 mm / 0.001 in : approx. 5 measurements / sec.
using 0.1 mm / 0.01 in : approx. 6 measurements / sec.
12/ Select scanning start channel ( in order to start all preset and tolerance inputs from this channel).