24
j) Setting the changeover contact activation time
This program setting allows you to define how long the changeover contact is activated during a valid access attempt
(default setting: 5 seconds); an interval of 1 - 99 seconds can be set.
When ‘0’ is set, the changeover contact goes to ‘toggle’ mode. Each valid access to the code lock changes the
changeover contact switch position. This can be used to enable/disable an alarm system.
Proceed as follows:
• Start programming mode as outlined in 8. a) so that the LED flashes red.
•
Enter the programming code to set the activation time. The LED lights up yellow.
•
Enter the desired changeover contact activation time. Possible is ..... (= 1 - 99 seconds; without leading
zero for single-digit memory numbers).
Example 1: Activation time is 8 seconds:
Example 2: Toggle mode:
•
Exit setting mode with the
button. The LED flashes red again. You can now carry out further programming or exit
programming mode with the button.
Example 1 for an 8-second activation time (programming mode must be active, see 8. a):
Example 2 for toggle mode (programming mode must be active, see 8. a):