14
a)
Enabling/disabling programming mode
•
To start programming mode, enter the master code on the IR remote control as follows (default setting = 123456):
The access system emits a short beep as confirmation each time a button on the IR remote control is pressed.
• The LED then flashes red (programming mode is active). You can now teach in/delete user transponders, for
example, or implement different settings.
•
To exit the programming mode, press the button. The access system is in standby mode again, the LED lights
up red continuously.
If no button is pressed within 30 seconds of calling up programming mode, the mode is exited automatically
for security reasons and the access system goes back to standby mode. Previously programmed settings
will be accepted.
b)
Changing the master code
Access system programming always requires the master code, which should be selected accordingly.
The default master code is ‘123456’ (the same applies after resetting the code lock to factory defaults). For security
reasons, we strongly recommend that you change this master code at the latest when programming is complete and
the access system is used in normal operation.
The master code must always consist of six digits.
Proceed as follows:
• Start programming mode as outlined in 8. a) so that the LED flashes red.
•
Enter the programming code for the master code. The LED lights up yellow.
•
Then, enter the new master code, for example:
•
Press the
key to confirm your entry.
•
Enter the new master code again, for example:
•
Press the
key to confirm your entry.
• The LED flashes red again. You can now carry out further programming or exit programming mode with the
button.