19
f)
Setting the user fingerprint
The access system can store up to 99 different user fingerprints. Memory numbers 0 - 98 are provided for these
transponders.
The teach-in process can be carried out via the IR remote control and with the aid of the master transponder or the
master fingerprint.
We recommend that you create a table and fill in all access data, including username, memory number.
This is how you can keep track of who accessed the access system and used a specific memory.
It is also very easy to delete a single user.
1) Teach-in of a user fingerprint with the IR remote control
You can teach in using the IR remote control in two different ways:
• Quick teach-in of a user fingerprint to the next free memory
• Teach-in of a user fingerprint to a specific memory
Automatically store user fingerprints to the next free memory:
This teach-in process is very fast and easy, new user fingerprints are taught in to the next available
memory.
In this case, however, deleting a specific user fingerprint is only possible with the fingerprint as the assign
-
ment between the user fingerprint and memory number is unknown. In that case, all memories would need
to be deleted.
• Start programming mode as outlined in 8. a) so that the LED flashes red.
•
Enter programming code to start the teach-in process. The LED lights up yellow.
• To teach in a user fingerprint, touch the fingerprint sensor 3 times in succession with the same finger. An LED ring
around the sensor lights up blue when the sensor is touched. The LED ring lights up green and a short beep is
emitted if the fingerprint is recognised correctly. After the third correct reading, the access system emits a longer
beep and the fingerprint is stored.
If the fingerprint cannot be read correctly, 3 beeps are emitted and the LED ring flashes red. The same
happens if you try to read in a fingerprint that has already been stored.
• You can now teach in another user fingerprint, proceed as outlined above (touch the fingerprint sensor 3x in suc
-
cession).
•
Exit teach-in mode with the
button. The LED flashes red again. You can now carry out further programming or
exit programming mode with the button.