DIAGNOSTICS & TROUBLESHOOTING
SWASH™ Clothing Care System
n
4-13
For Service Technician Use Only
Strip Circuits
Pod / Reservoir Switches
Pump
Fan Motor
Heater
L1
N
FAN MOTOR
RELAY
FAN
MOTOR
THERMAL
FUSE
FAN MOTOR
P7-1
NOTE: Check Thermal Fuse if open circuit is detected.
BK
LBU
W
J2-12
J1-11
W
P7-2
BOTTOM TRAY
13.1
Ω
M
ACU BOARD
L1
N
11.5
Ω
HEATER
RELAY
HEATER
ELEMENT
THERMAL
CUTOFF
HEATER
P6-1
HIGH LIMIT
THERMOSTAT
NOTE: Check TCO & High Limit if open circuit is detected.
BK
V
W
J2-12
J2-7
W
P6-2
BOTTOM TRAY
ACU BOARD
L1
N
PUMP
RELAY
PUMP
PUMP
P5-1
NOTE: Check pump resistance if open circuit is detected.
BK
V
W
J2-12
J1-10
W
P5-2
???
Ω
P
ACU BOARD
POD / RESERVOIR SWITCHES
ACU BOARD
J3-2
J3-3
J3-4
POD SWITCH
ACU BOARD
RESERVOIR
SWITCH
POD SENSOR SWITCH
RESERVOIR SENSOR SWITCH
B
R
Y
R
GND
THERMISTOR
ACU BOARD
THERMISTOR
J3-6
ACU BOARD
J3-5
10k
Ω ∗
* Approximate value measured
at room temperature
R/W
R/W
TEMP 2
TEMP1
Thermistor
CUP SENSOR SWITCH
CUP SWITCH
Summary of Contents for SFF1000CSA series
Page 10: ...1 6 n SWASH Clothing Care System GENERAL INFORMATION Notes ...
Page 20: ...2 10 n SWASH Clothing Care System OPERATION Notes ...
Page 33: ...COMPONENT ACCESS SWASH Clothing Care System n 3 13 Notes ...
Page 34: ...3 14 n SWASH Clothing Care System COMPONENT ACCESS Notes ...
Page 48: ...4 14 n SWASH Clothing Care System DIAGNOSTICS TROUBLESHOOTING Notes ...