DIAGNOSTICS & TROUBLESHOOTING
SWASH™ Clothing Care System
n
4-11
Figure 3
For Service Technician Use Only
Appliance Control Unit (ACU)
J3 - Thermistor, Cup &
Reservoir Switches
P19 - User Interface
J2 - L1 & Heater
J1 - Neutral, Pump, & Fan Motor
ACU CONNECTOR PIN-OUTS
CONNECTOR J1
(Neutral, Pump, and Fan Motor)
J1-9
Neutral from plug
J1-10 Pump
J1-11 Fan Motor
CONNECTOR J2
(L1 and Heater)
J2-7
Heater Assembly
J2-12 L1 from plug
APPLIANCE
CONTROL
UNIT
CONNECTOR J3
(Pod Switch, Reservoir Switch, and Thermistor)
J3-2
Switch, Cup Sensor
J3-3
Switch, Reservoir Sensor
J3-4
Switch, GND
J3-5
Thermistor (Temp 2)
J3-6
Thermistor (Temp 1)
CONNECTOR P19
(User Interface)
P19-2 +5 VDC
P19-3 Ref GND
P19-4 DATA