Chassis Intrusion
The Chassis Intrusion Detector is
located on JL1. See chapter one,
board layouts, and PC Health Moni-
tor page 1-18 for more information.
See Table 2-18 for pin definitions.
Pin
N u m b e r
1
2
Definition
Intrusion Input
G r o u n d
Table 2-18
Chassis Intrusion
Detector Settings on
JL1
2-9
Installing the DIM Modules
CAUTION
Exercise extreme care when installing or removing the DIM
modules to prevent any possible damages.
DIM Module Installation
1.
Insert DIM modules in Bank 0 through Bank 3 as required for the
desired system memory.
2.
Insert each DIM module vertically into its socket. Pay attention to the
two notches to prevent inserting the DIMM at a wrong position. The
component side of the DIM module must face the CPU socket. The
prior statement is applicable for DIMMs with components on one side
only.
3.
Gently press the DIM module until it snaps upright into place in the
socket.
4.
For best results, install DIMM starting from bank 0 (the DIMM socket
farthest from BX chip)
Open = Default, Close = Intrusion