Confi guring the LSI MegaRAID Settings
2-27
2-10 Checking Data Consistency of a Disk Drive
The LSI MegaRAID Software allows the user to check data consistency between the
source drive and its mirrored drive (the target drive) for RAID 1 or RAID 10 arrays.
Any differences found between these two drives will be automatically corrected if
you run Check Consistency.
Checking Data Consistency
Follow the steps below to check data consistency between the source drive and
the mirrored drive for RAID 1 and RAID 10 arrays.
From the LSI Main Menu, select Check Consistency and press <Enter>.
1.
A list of confi gured virtual drives will be displayed. Using the up/down arrow
2.
keys, select the virtual drive for which you wish to check data consistency
and press <Spacebar>.
Note
: If a RAID 0 drive has been selected, a message will appear, indicat-
ing that Check Consistency cannot be performed. To continue, deselect
this drive, select a redundant drive and press <Spacebar> again.