LSI MegaRAID Confi guration for the LSI 1068 Controller User's Manual
2-24
Viewing the Properties of a Physical Drive
From the LSI MegaRAID Main Menu, select Objects and press <Enter>.
1.
When the Objects submenu appears, select Physical Drive and press <En-
2.
ter>.
When the screen of all available Physical Drives appears as shown on Page
3.
2-21, using the arrow keys, select the drive whose properties you wish to
view and press <F2>. The properties of the drive you selected will appear as
follows.
Note
: The properties (parameters) of a physical drive shown on the screen
are for display only. You cannot update or change the properties or pa-
rameters of a physical drive.
Viewing and Updating the Properties of an Adapter
From the LSI MegaRAID Main Menu, select Objects and press <Enter>.
1.
When the Objects submenu appears, select Adapter and press <Enter>.
2.
Select the adapter whose properties you wish to view/update and press <En-
3.
ter>. The properties of the Adapter you selected will appear.
If you wish to change the value of a parameter (property), select the param-
4.
eter and press <Enter>.
Type a different value for this parameter (property) and press <Enter>.
5.
After you have fi nished all the changes, press <Esc> to return to the LSI
6.
MegaRAID Main screen.