8
(
6
)
Wiper label
Properly use wiper.
(
7
)
Filter core safety label
Replace pilot oil filter every 400 hours
Stop machine on a firm and level ground.
Lower bucket to the ground.
Run engine at low-speed for 5 minutes.
Shut down engine, remove the key.
Relieve internal pressure which builds up in
hydraulic system by means of left/right pilot
joystick.
Set pilot control lever in LOCK (UP) position.
Use wrench for filter to remove filter housing
off the filter head cover by rotating
counterclockwise.
Remove filter core and used 0-ring.
Clean the area in contact by head cover and
o-ring.
Apply a new layer of fresh hydraulic oil, and
place it in position.
Lubricate new filter core with a thin layer of
clean hydraulic oil on the ring section. Push
filter core upward while moving it forward and
backward alternately to install it.
Clean filter housing.
Rotate clockwise to tighten filter shell to head
cover. Tighten at torque: 19.5—29.5Nm (2-3
kgfm).