6
(
4
)
Machine posture symbol
Caution
Do not start engine when hydraulic
oil tank runs out of oil.
Inspect hydraulic oil level……daily
Park machine on level ground.
Completely retract arm cylinder and extend
bucket cylinder to full length.
Lower bucket down to the ground.
Run engine at low speed for 5 minutes.
Shut down engine, remove the key.
Place pilot control lever to LOCK (up)
position.
Open right side door to check oil level gauge.
Located on hydraulic oil tank, oil level must be
within level marks. Pump oil if level is higher
than MAX mark, refill if level is below MIN
mark.
add oil
:
Remove upper breather screw cap by rotating
anticlockwise.
Refill oil through strainer. Recheck oil level
gauge.
Fasten cap securely.