No. 7, Road 12, Industrial Zone, Taichung City 407, Taiwan
Tel: 886-4-2359-1190 Fax: 886-4-2359-3409
[email protected] www.sunriseiw.com.tw
27
4.
Oil temperature
:
The oil temperature should be under 50 degrees Celsius. If the upper/lower
limit switches are not set correctly for unloading of the pump, the oil
temperature can raise quickly. Adjust the limit switches so the pump will be in
the unloading condition.
5.
Hydraulic pressure
:
The working pressure of the hydraulic system is pre-set in the factory. There is
a pressure gauge to indicate the working pressure of the machine. The pressure
gauge should normally be closed and be used only during service/maintenance
work.
Model
HBM-40NC
HBM-75NC
Max Pressure
210
Kg/cm
2
210
Kg/cm
2
AIRBORNE NOISE
The continuous airborne noise level of the machine under normal condition is
approximately 75 dB
±
5 dB.