Settting Screens:
In the setting screen, the Function key allows switching between the NC SET (NC
backgauge setting parameters) and CY SET (cylinder setting parameter). Press the
PROGRAM button goes to the program screen.
CY SET SCREEN
HOLD TIME: In CONTINUOUS mode, the cylinder moves back and forth between
the FWD and BACK positions. At the FWD position, the cylinder can hold
for a while before moving back. The hold time set this temporary pause time
at the FWD position. If set to zero, the cylinder moves back immediately.
ORIGIN SET: the origin position of the cylinder after calibration. Adjust this
parameter if the cylinder position is off.
Δ
FORWARD: If the Forward position is off from the set value, use this field to
fine adjust the difference.
Δ
BACK: If the BACK position is off from the set value, use this field to fine adjust
the difference.