No. 7, Road 12, Industrial Zone, Taichung City 407, Taiwan
Tel: 886-4-2359-1190 Fax: 886-4-2359-3409
[email protected] www.sunriseiw.com.tw
26
MAINTENANCE
1.
Before operating the machine
:
Routinely check the electrical power cable and the foot switch cable for any
loosening or damage.
Clean all slugs, cut off pieces, and other waste material from and around the
machine.
2.
Filter and Oil Change
:
Take off and clean the suction filter inside the oil tank every time when
changing oil. The first oil change should be performed after approximately
600 operating hours. Further oil change is needed for every 1200 operating
hours. A drain outlet is located at the base of the oil tank.
Screw back the cleaned suction filter after the draining the oil. If the suction
filter is damaged or clogged, replace the suction filter. Do not mix different
brands of oil.
Hydraulic Fluid (or equivalent)
Mobil
DTE
46
Esso
Nuto
H46
Shell
Tellus 46 or Hydraulic oil 46
B.P.
Energol
HLP
46
Castrol
Hyspin AWS 46 6018
3.
Oil level
:
Make sure the hydraulic oil level is in the range indicated on the oil level gauge.
It is better to keep the oil level close to the high mark indicated on the gauge.