CONTROL PANEL
ISOLATOR Switch
- This switch controls the main electric source. It also
functions as a lock for the electric box. At the ON position the switch locks the
electric box and enables you to start the machine. At the OFF position, the power
is cut off and the electric box can be opened.
EMERGENCY STOP
- Use the EMERGENCY STOP button to stop the machine
in an emergency. The Emergency button must be released before the PUMP ON
button will function. To release it, turn knob slightly to the right.
I (PUMP ON)
- Push this button to turn on the machine. The EMERGENCY
STOP button must be released before the PUMP ON button will function. The green
POWER LIGHT stays on when the machine is turned on.
O (PUMP OFF)
- Push this button to turn off the machine.
FORWARD (TWO-HAND SWITCHES)
– Use these switches to operate the
machine cylinder movement. Both switches must be pressed at the same time for
the cylinder movement.
NEVER has one operator hold the material and
another operator operating the machine.
BACK
– Use these switches to move the cylinder backward in JOG mode.
HAND/PADDLE -
Use this switch for choosing operation by the two-hand
switches or with foot paddle.