17
The NC stopper function can be turned off. By press the NC gauge button for 2
seconds, the NC function is turned to OFF and the stopper moves back to the origin
position. Press for another 2 seconds to turn the NC function back ON, but the
stopper stay at origin position.
If the NC Gauge function is turned ON, press the NC start button 2 seconds and
moves the NC stopper to the position set by STEP 1 GAUGE. Then press the two
forward buttons or the foot paddle to execute the STEP 1 bend. After STEP 1 is
completed, if there is more steps, the NC stopper will move automatically to the
position set by STEP 2 GAUGE. The NC START is only for the first STEP.