Device address range: 1-247.
Addr 001
Modbus param
Baud rate can be set to 9600bps or
19200bps.
Parity can be set to NO, ODD or EVEN.
Stop bit can be set to 1b or 2b.
Baud [9600]
Parity [ NO ]
Stop bit [1]
Uart param
10.13
Advanced Parameters Setting
The inverter provides a variety of advanced protection features.
Main Screen(Press
ENTER
)
→
Menu screen(Press
×
3)
→
Set-param (Press
ENTER
)
→
Enter password (Press
ENTER
, Press
×
4)
→
Advanced settings(Press
ENTER
)
10.13.1 PVS Detect Settings
Main Screen(Press
ENTER
)
→
Menu screen(Press
×
3)
→
Set-param (Press
ENTER
)
→
Enter password (Press
ENTER
, Press
×
4)
→
Advanced settings(Press
ENTER
)
→
PVS Detect(Press
ENTER
)
A password confirmation screen will occur. Press
to
move cursor right and Press
to input the password
111111.
Advanced settings
Password:
000000
User can only check the parameter in this interface. The default values of the
advanced parameters have been preset as per grid code of corresponding countries.
To set the advanced parameters , please contact Sungrow to acquire advanced
password.