User Manual
90
Parameters
SG36KTL-M
Protection
DC reverse connection protection
Yes
AC short-circuit protection
Yes
Leakage current protection
Yes
Grid monitoring
Yes
DC switch / AC switch
Yes / No
DC fuse
Yes (positive, 15A)
PV string current monitoring
Yes
Overvoltage protection
DC Type II / AC Type II
General Data
Dimensions (W*H*D)
525*740*240 mm
Weight
48 kg
Isolation method
Transformerless
Degree of protection
IP65
Night power consumption
< 2 W
Operating ambient temperature
range
-25 to 60
℃
(> 50
℃
derating)
Allowable relative humidity range
(non-condensing)
0 – 100 %
Cooling method
Smart forced air cooling
Max. operating altitude
4000 m (> 3000 m derating)
Display / Communication
Graphic LCD / RS485
DC connection type
MC4 (Max. 6 mm² )
AC connection type
Screw clamp terminal (Max. 50 mm² )
Compliance
IEC 62109, IEC 61727, IEC 62116, IEC 60068,
IEC 61683, CE, IEC 61000-3-11/-12, VDE
0126-1-1,
VDE-AR-N-4105, CEA
Grid support
LVRT, HVRT, active & reactive power control and
power ramp rate control
Type designation
SG36KTL-M-10