4-14
StorEdge L280 Service Manual • February 1998
4.10.1
Field Replaceable Units (FRUs)
Note –
A FRU is a part that can be replaced in the field.
When an error occurs, press Enter then Next to obtain information about the
following FRU messages.
TABLE 4-6
describes what each FRU display message means
and the recommended replacement procedure.
4.10.2
Recovery
If the Autoloader does not recover from an error in normal operation, remove the
magazine and all the tapes and power cycle. If the Autoloader fails again, it must be
exchanged. If the Autoloader powers up successfully, reload the tapes and retry the
failed operation. If the Autoloader does not recover from an error in normal
operation, remove the magazine and all the tapes and power cycle. If the Autoloader
files again, it must be exchanged. If the Autoloader powers on successfully, reload
the tapes and retry the failed operation.
TABLE 4-6
FRUs (Field Replaceable Units)
FRU Number displayed
on front panel
Probable Cause of Failure
Recommended Replacement
FRU #1
SCSI controller
Unit minus the drive
FRU #7
Drive
Drive
FRU #28
Loader mechanics
Unit minus the drive
TABLE 4-7
Error Codes
Hex Error
Probable Cause
01H
ROM checksum error.
02H
Register error.
03H
Microprocessor error.
04H
Controlled area of RAM checksum error.
05H
RAM test error.
06H
SCSI chip error.
07H
Library controller chip error.
2DH
Door is open.
Summary of Contents for StorEdge L280
Page 10: ...x StorEdge L280 Service Manual February 1998 ...
Page 11: ...xi ...
Page 12: ...xii StorEdge L280 Service Manual February 1998 ...
Page 16: ...xvi StorEdge L280 Service Manual February 1998 ...
Page 20: ...xx StorEdge L280 Service Manual February 1998 TABLE 5 3 Solenoid Mechanism 5 10 ...
Page 44: ...1 20 StorEdge L280 Service Manual February 1998 ...
Page 52: ...2 8 StorEdge L280 Service Manual February 1998 ...
Page 86: ...4 22 StorEdge L280 Service Manual February 1998 ...
Page 98: ...5 12 StorEdge L280 Service Manual February 1998 ...