Chapter 12
Servicing Sun StorEdge 6020 Arrays
12-7
3. From the Storage Automated Diagnostic Environment main window, click
Manage.
4. Click the Service link.
5. From the left pane, click Ethers.
This will update the
/etc/ethers
file.
6. Enter the MAC address for the replacement array and click on the Update Ethers
button.
Caution –
Be sure to assign the MAC address for the Sun StorEdge 6020 arrays to
the correct array position in the Sun StorEdge 6320 system. IP address assignments
are listed in Chapter 3.
7. Reboot the Sun StorEdge 6020 array to enable RARP to set the IP address.