N
AME
: T
RAINING
D
EPARTMENT
D
ATE
: 2017
P
AGE
:
25 / 59
R
EFERENCE
: T
ECHNICIAN
’
S
O
PERATING
M
ANUAL
X40+-X50+ ISOBUS
I
ND
03
+
+
5
-
T
RIBORD
ACTUATOR
D2.2
3- Display of malfunction alarms :
If there is no feedback from the actuator or if it is inactive,
the following alarms are triggered:
"TRIBORD DROITE ACTUATOR PROBLEM" (TRIBORD RIGHT ACTUATOR
PROBLEM)
"TRIBORD GAUCHE ACTUATOR PROBLEM" (TRIBORD LEFT ACTUATOR
PROBLEM)
4- Diagnostics on the console :
From the
HOME
menu, make sure that the shutters are closed
Access the
ADVANCED SETTINGS
menu with
Select
"Diagnostique" (Diagnostics)
And press the key
To check an actuator, perform a complete extension of the rod.
100 pulses
± 2 and a 50 mm stroke should be obtained
If there is a fault, the screen displays
"Bloqué" (Jammed)
Left actuator
extension control
Left actuator
retraction control
Right actuator
extension control
Right actuator
retraction control
Left Tribord
Actuator
Actuator status
OK/Moved
/Jammed
Right Tribord
actuator
Actuator status
OK/Moved
/Jammed
Actuator return:
Rod extension: