5
-
W
EIGHING
DEVICE
SENSOR
C6.2
Checking the weighing device sensor is only carried out after a positive diagnosis of the link between the CAN and ECU and a weight
indicator supply voltage.
1-
When checking the sensor the spreader must be unhitched.
2-
Place a nut on the pressure screw
1
to compress the spring so there is no
strain on the weighing beam.
3-
Completely disconnect the weight indicator in the connection box
2
and
uncouple the grey wire from the blue wire
4-
Check the values opposite.
The weighing device sensor is considered to be compliant if it meets all these
indications.
S
ENSOR
BRAND
V
ISCHAY
R
BETWEEN
THE
BROWN
AND
BLUE
WIRES
385 Ω +/- 10
R
BETWEEN
THE
GREEN
/
YELLOW
AND
BLACK
WIRES
353 Ω +/- 3
R
BETWEEN
THE
GREY
WIRE
AND
EACH
OF
THE
4
OTHER
WIRES
N
O
CONTINUITY
1