5
-
II - D
IAGNOSTIC
PROCEDURES
D
IAG
-4
4 - T
HE
APPLICATION
RATE
ELECTRIC
ACTUATOR
(
S
)
DOES
/
DO
NOT
MOVE
The application rate
electric actuator(s)
does/do not move
Is only one actuator
faulty or both?
Only 1 actuator
Both actuators are
faulty
Check in the
«DIAGNOSTICS» menu
(Sheet D1)
Check the presence
of a forward speed
The faulty electric
actuator still does not
work
Inversion of the
phenomenon
Check the
programming of
the working width
Reverse the actuators
in the connection box
Check that the
kg/ha dose is possible
to perform
Check the «T Factor»:
0.6> T<1.4
Replace the
connection box
(Sheet A3)
Replace the actuator