N
AME
: T
RAINING
D
EPARTMENT
D
ATE
: 2017
P
AGE
:
33 / 59
R
EFERENCE
: T
ECHNICIAN
’
S
O
PERATING
M
ANUAL
X40+-X50+ ISOBUS
I
ND
03
1. End of hopper sensor characteristics:
The end of hopper sensors are capacity sensors which are normally open. The
presence or absence on contact of the sensor is translated into a 0 - 12 V signal.
A red diode lights up at the back of the sensor when the front of the sensor
comes into contact with a target.
2. Alarm display:
When working, when a sensor is uncovered for over 10 seconds, the alarm
opposite activates. A red arrow indicates the side in question.
If the side opposite is greyed out, the sensor is still covered with product.
3. Programming:
On the universal terminal, access the
ADVANCED SETTINGS
menu
Select
Actuators & sensors
Enter the PIN code
1936
and confi rm.
Press
to display the
LEVEL sensors
page.
LEVEL sensors
_
=> To activate the option
4. Checking a sensor:
Measure the tension between the blue wire terminals and the yellow/green
wire:
ᇗ
Sensor without product contact => ≈ 12 V and red diode on sensor off .
ᇗ
Sensor with product contact => ≈ 0 V and red diode on sensor on.
E
ND
OF
HOPPER
SENSOR
D6
W
IRE
COLOUR
F
UNCTION
B
ROWN
+ 12 V
B
LUE
0 V
Y
ELLOW
G
REEN
S
IGNAL
+
+
5
-