D2.3
5- Actuator position control
Control the actuators from the
DIAGNOSTIQUE
(Diagnostics) menu in the
diff erent positions
The Ø 4 mm holes should be aligned:
Ⴠ
0mm
ᇗ
Position
1
(Normal Spreading)
Ⴠ
35mm
ᇗ
Position
2
Ⴠ
50mm
ᇗ
Position
3
If not, adjust the actuator attachment
A
and align the Ø 4 mm holes for 0 mm
ᇗ
Position
1
6- Electric control with pulse counter and/or multimeter
It is also possible to control an electric actuator, using a direct power supply
and a pulse counter.
ᇗ
Connect a +/- or -/+ power supply on the red and blue wires, the rod will
extend or retract.
There is a limit switch. On the 2 other wires (black and white) it is possible
to count the pulses with a specifi c counter (e.g. “Omron H7EC”, etc). There
should be 100 pulses for a complete extension or retraction of the rod.