N
AME
: T
RAINING
D
EPARTMENT
D
ATE
: 2017
P
AGE
:
12 / 59
R
EFERENCE
: T
ECHNICIAN
’
S
O
PERATING
M
ANUAL
X40+-X50+ ISOBUS
I
ND
03
+
+
5
-
S
HUTTER
GUIDE
SETTINGS
B5
When a shutter guide
1
is too tight, it can cause jamming at a shutter opening, before it comes
to a stop with its application rate lever
2
.
ᇗ
Check there is a
1 mm
clearance between the bowl and the shutter with the spreader loaded.
ᇗ
To adjust:
1.
Remove the H6 nut of the anti-bounce device
3
2.
The shutter guide is mounted on a slot. Using screws
4
and
5
set a 1 mm clearance between the shutter and the bottom of
the metering mechanism. It is preferable to make a slightly bigger adjustment for the upper section
5
.
3.
Put back the anti-bounce device and its nut
3
.
1
2
3
5
4