Page 61
DUAL FUEL RANGE ERROR CODES
Base
Error
Code
Extended
Error Code
Error Description
Displayed Phrase
Priority
Service Instruction
03
Keypad FMEA error
Keypad FMEA error
1
04
Keypad EE CRC error
Keypad EE CRC error
1
05
Keypad mains sync error
Keypad mains sync error
3
09
00
UIM EE checksum error
UIM EE checksum error
3
Replace UIM Module
01
UIM configuration data CRC
error
UIM configuration data CRC error
1
02
UIM fuse error
UIM fuse error
1
03
UIM ambient thermistor open
error
UIM ambient thermistor open error 3
04
UIM ambient thermistor shorted
error
UIM ambient thermistor shorted
error
3
05
LCD module error
LCD module error
1
System Failures
10
00
Communications error detected
by the UIM
Communications error detected
by the UIM
2
Check com harness, replace Relay
Module
01
Communications error detected
by the RM
Communications error detected
by the RM
2
Check com harness, replace UIM
Module
11
00
Overtemp error - door unlocked
X oven
Overtemp error - door unlocked
2
Check door motor assembly &
wiring, replace Relay Module
01
Overtemp error - door locked X
oven
Overtemp error - door locked
2
Replace Relay Module
12
00
RM Ambient overtemp error
RM Ambient overtemp error
2
Check air flow, verify cooling fan
operational, replace relay module
13
00
UIM Ambient overtemp error
UIM Ambient overtemp error
2
Check air flow, verify cooling fan
operational, replace UIM.
14
00
Self-clean rate-of rise error
Self-clean rate-of rise error
3
Check oven for leaks, insulation
problems. Run diagnostics, look for
open outputs or loads
15
00
LPM error
2
Dual Fuel Range Error Codes
service.subzero.com
814889
REV.
A
.1
02/2018