Page 46
International Dual Fuel (ICBDF) Series
International Dual Fuel (ICBDF) Series
Component Access & Removal
4-16
#814889- Revision A - July, 2010
Figure 4-39. Convection Baffle Removal.
Oven Compartment Components
Left and Right Rack Guide Removal
First, remove oven racks. Then, extract the screws in
each corner, top and bottom of the rack guide and lift
guide out.
NOTE
:
On units starting with serial #16000000 the oven
rack guides remove without extracting any screws.
Simply lift upwards on the rack to disengage the shoulder
screw from the keyhole slot on the rack guide and
remove (See
Figure 4-38
).
Oven Light Removal
To remove the oven light you will need to remove the
oven racks and guides. Next, the light cover will need to
be removed by gently pulling the light cover off the light
housing. Now, to remove the light bulb, lift the bulb
straight up and out of the light bulb socket.
NOTE
:
When replacing the light bulb with a new one,
wrap a clean cloth around the new bulb so fingerprints
are not left on the new bulb. The greasy residue from
fingerprints may cause the new bulb to burn out prema-
turely.
Convection Baffle Plate Removal
First, the racks and rack guides will need to be removed.
Now, extract the screws in each corner, the top and bot-
tom of the convection baffle plate and remove (See
Figure 4-39
).
Convection Fan Assembly Removal
The racks, rack guides and convection baffle plate will
need to be removed first. Then, extract the screws
around the convection fan and the top screw located
between the element (where the element goes through
the oven cavity) (See
Figure 4-40
). Now, pull fan assem-
bly into oven cavity and disconnect wiring and remove.
Broil Element and Broil Pan Removal
To have more room when removing the broil element,
remove the racks from the unit. Next, extract the four
screws that secure the element and broil pan to the ceil-
ing of the oven cavity. Now, extract the two screws that
secure the element leads through the oven cavity. Then,
pull the element forward and down into the oven cavity
until the terminals and wires are exposed. Now, discon-
nect the wires and remove the element and broil pan
(See
Figure 4-41
).
Smoke Catalyst Removal
The catalyst is located in the rear ceiling of the oven cavi-
ty. To remove, extract the two screws and pull catalyst
straight down and remove (See
Figure 4-41
).
Figure 4-41. Broil Element and Smoke Catalyst
Removal.
Figure 4-40. Convection Fan Removal.
Figure 4-38. Removable Rack Guides.