International Dual Fuel (ICBDF) Series
International Dual Fuel (ICBDF) Series
Operation & Electronic Control
3-20
#814889 - Revision A- July, 2010
TESTING THE OVEN RELAY BOARD
Element Testing
First access diagnostic mode. Once in diagnostic mode, the technician can turn the oven control knob bezel to acti-
vate an element. The element relay and the double line breaker(dlb) will close to complete a 230 VAC circuit through
a specific element. If the oven controller detects the current running through the closed circuit, the
**
CFH light will be
illuminated.
NOTE
:
Diagnostic Mode will end 2 minutes after last key stroke or when the CLEAR key is pressed.
Figure 3-66. Element Testing Chart
**
Call For Heat
Turn Bezel (Cooking Mode)
Relay(s) Activated
Response
Stone
(Use “PROOF” for 18” Cavity)
Clean
Conv Roast
Conv Broil
Conv Bake
Left Convection Element
Right Convection Element
Inner Bake Element
Broil Element
Outer Bake Element
**
CFH Indicator Light Illuminates
**
CFH Indicator Light Illuminates
**
CFH Indicator Light Illuminates
**
CFH Indicator Light Illuminates
**
CFH Indicator Light Illuminates
RTD Testing
First access Diagnostic Mode. Once in diagnostic mode, the RTD temperature is shown in display window of tem-
perature control knob. If the RTD is open, “Err 03” will be shown in the display of the electronic control housing. If the
RTD is shorted, “Err 04” will be shown in the display of the electronic control housing.
NOTE
:
Diagnostic mode will end 2 minutes after last key stroke or when the ENTER key is pressed.
Probe Testing
First access Diagnostic Mode. Next, press the PROBE key
(this will switch the readout to probe temperature as shown
in the display window of the temperature control knob)
. If the probe has not been inserted, “out” will be shown as the
probe temperature in the display window of the temperature control knob. If the probe is shorted, “Err 09” will be shown
in the display of the electronic control housing.
NOTE
:
Diagnostic Mode will end 2 minutes after last key stroke or when the ENTER key is pressed.